TECHNICAL DATA

Applicable Standard
EN 60051
NOMINAL CURRENT(A)
-
NOMINAL FREQUENCY  (Hz)
-
OPERATION METHOD
Coil
ACCURACY CLASS
1
LOAD(VA)
max.2
DISPLAY UNIT
Ampere
DISPLAYED AMPLITUDE
0-120%
LINEER / NON-LINEAR
Lineer
SCALE RANGE (ANGLE)
240
 0 POSITION
Lateral
0 ADJUSTMENT RANGE
min.±5°
STOPPER AGAINST EXTREME DEFLECTION OF POINTER 
YES
DEFAULT (ERROR)
-
AMBIENT TEMPERATURE
0,05 %/°C
AMBIENT HUMIDITY
20...80 % RH
VARIATION DUE TO SELF-HEATING
max.0,2%
CONTINUOUS OVERLOAD
20%
TRANSIENT OVERLOAD
200%
MIN./MAX.TEMPERATURES
-20...+60  °C
DIMENSİONS
96x96x65 mm
CASING

Plastic Case, plastic frame, fiber glass reinforced plastic base , front glass